Preserving accurate differences in pressure is essential in controlled-environment testing, whether in gloveboxes, chambers, cleanrooms, or environmental test enclosures.ย  The 90001848 Differential Low Pressure Sensor from Electro-Tech Systems is designed to work in combination with their M-5300 Series EnviroPro PLC controllers to provide constant, dependable, and highly accurate chamber pressure monitoring.

๐—ช๐—ต๐˜† ๐—–๐—ต๐—ฎ๐—บ๐—ฏ๐—ฒ๐—ฟ ๐—ฃ๐—ฟ๐—ฒ๐˜€๐˜€๐˜‚๐—ฟ๐—ฒ ๐—ฆ๐˜๐—ฎ๐—ฏ๐—ถ๐—น๐—ถ๐˜๐˜† ๐— ๐—ฎ๐˜๐˜๐—ฒ๐—ฟ๐˜€?

A sealed glovebox or dry-gas dehumidification system may experience different gas distribution because of even small pressure changes.ย  In pharmaceuticals, semiconductor manufacturing, materials research, and biological settings, this mismatch can lead to moisture gradients, chemical irregularities, and eventually jeopardize test findings.ย  ETS understands that maintaining a stable surroundings needs more than just controlling temperature and humidity; controlling pressure is as important.

๐—ข๐˜ƒ๐—ฒ๐—ฟ๐˜ƒ๐—ถ๐—ฒ๐˜„: ๐—˜๐—ง๐—ฆ 90001848 ๐——๐—ถ๐—ณ๐—ณ๐—ฒ๐—ฟ๐—ฒ๐—ป๐˜๐—ถ๐—ฎ๐—น ๐—Ÿ๐—ผ๐˜„ ๐—ฃ๐—ฟ๐—ฒ๐˜€๐˜€๐˜‚๐—ฟ๐—ฒ ๐—ฆ๐—ฒ๐—ป๐˜€๐—ผ๐—ฟ

The ETS 90001848 sensor is a compact, robust pressureโ€‘monitoring device. Key specifications include:

Data logging, alarm/threshold functionality, and comprehensive real-time monitoring are made possible by a smooth interface with an ETS Mโ€ฏ5300 Series EnviroPro PLC controller. These features are essential for preserving safe operating settings and quickly detecting deviations.

๐—œ๐—ป๐˜๐—ฒ๐—ด๐—ฟ๐—ฎ๐˜๐—ถ๐—ผ๐—ป ๐˜„๐—ถ๐˜๐—ต ๐— โ€ฏ5300 ๐—ฆ๐—ฒ๐—ฟ๐—ถ๐—ฒ๐˜€ ๐—˜๐—ป๐˜ƒ๐—ถ๐—ฟ๐—ผ๐—ฃ๐—ฟ๐—ผ ๐—ฃ๐—Ÿ๐—–

When combined with ETS’s EnviroPro controller system, the sensor gains extra power.ย  These upscale units consist of:

This combination ensures consistent, reproducible testing conditions by providing engineers and technicians with exact control over pressure, and therefore, humidity and temperature.

๐—”๐—ฝ๐—ฝ๐—น๐—ถ๐—ฐ๐—ฎ๐˜๐—ถ๐—ผ๐—ป๐˜€ ๐—”๐—ฐ๐—ฟ๐—ผ๐˜€๐˜€ ๐—œ๐—ป๐—ฑ๐˜‚๐˜€๐˜๐—ฟ๐—ถ๐—ฒ๐˜€

A variety of fields are supported by ETS pressure sensors and controlling systems:

๐—œ๐—ป๐˜€๐˜๐—ฎ๐—น๐—น๐—ฎ๐˜๐—ถ๐—ผ๐—ป & ๐— ๐—ฎ๐—ถ๐—ป๐˜๐—ฒ๐—ป๐—ฎ๐—ป๐—ฐ๐—ฒ

There is not much work involved in installing the ETS 90001848 pressure sensor.ย  It uses either the Micro-USB (for power/data) or the quick-lock connector to connect to the EnviroPro controller.ย  In typical lab settings, maintenance is essentially nonexistent and is regarded as maintenance-free.

ETS provides calibrated service support and RMA processes through their Perkasie, Pennsylvania-based service staff in the event that repairs are required.

๐—ง๐—ฟ๐—ผ๐˜‚๐—ฏ๐—น๐—ฒ๐˜€๐—ต๐—ผ๐—ผ๐˜๐—ถ๐—ป๐—ด & ๐—ฆ๐˜‚๐—ฝ๐—ฝ๐—ผ๐—ฟ๐˜

Common problems like “no power” or “no pressure reading” are typically caused by malfunctioning power connectors or incorrectly configured controllers, according to the troubleshooting advice provided by ETS.ย  Matching the sensor with approved ETS hardware lowers integration complexity and support costs because it is only compatible with the Mโ€ฏ5300 series EnviroPro system.

๐—•๐—ฒ๐˜€๐˜ ๐—ฃ๐—ฟ๐—ฎ๐—ฐ๐˜๐—ถ๐—ฐ๐—ฒ๐˜€ ๐—ณ๐—ผ๐—ฟ ๐—ฆ๐˜๐—ฎ๐—ฏ๐—น๐—ฒ ๐—ง๐—ฒ๐˜€๐˜ ๐—˜๐—ป๐˜ƒ๐—ถ๐—ฟ๐—ผ๐—ป๐—บ๐—ฒ๐—ป๐˜๐˜€

  1. Pair the ETS sensor with a compatible Mโ€ฏ5300 EnviroPro controller to leverage realโ€‘time logging and alarms.
  2. Configure threshold alarms so that deviationsโ€”however subtleโ€”are flagged immediately.
  3. Ensure power wiring (12โ€“30โ€ฏVDC) is correct and secure, including tight connection of the quickโ€‘lock aviation plug.
  4. Use calibration services through ETS: their ISOโ€ฏ17025 lab can validate sensor accuracy periodically.
  5. Leverage data logging features from the controller to analyze trends, validate performance, and document compliance for regulated environments.

๐—ช๐—ต๐˜† ๐—–๐—ต๐—ผ๐—ผ๐˜€๐—ฒ ๐—˜๐—ง๐—ฆ?

๐—˜๐˜…๐—ฝ๐—ฒ๐—ฟ๐—ถ๐—ฒ๐—ป๐—ฐ๐—ฒ ๐˜€๐—ถ๐—ป๐—ฐ๐—ฒ 1976: ETS has established a solid reputation as a pioneer in environmental measurement and static-control technologies in a variety of sectors, including petrochemicals, pharmaceuticals, and aerospace.

๐—–๐—ผ๐—บ๐—ฝ๐—น๐—ฒ๐˜๐—ฒ ๐—ฒ๐—ป๐˜ƒ๐—ถ๐—ฟ๐—ผ๐—ป๐—บ๐—ฒ๐—ป๐˜๐—ฎ๐—น ๐—ฐ๐—ผ๐—ป๐˜๐—ฟ๐—ผ๐—น ๐—ฒ๐—ฐ๐—ผ๐˜€๐˜†๐˜€๐˜๐—ฒ๐—บ: ETS offers environmental chambers, humidifiers, dehumidification systems, gloveboxes, and controllers for all-encompassing solution delivery in addition to pressure sensors.

๐—–๐˜‚๐˜€๐˜๐—ผ๐—บ๐—ถ๐˜‡๐—ฎ๐˜๐—ถ๐—ผ๐—ป ๐—ฎ๐—ป๐—ฑ ๐˜€๐—ฒ๐—ฟ๐˜ƒ๐—ถ๐—ฐ๐—ฒ: ETS provides long-term support according on user needs and offers design and calibration consultation for unique chamber or enclosure needs.

๐—ฆ๐—ฎ๐—บ๐—ฝ๐—น๐—ฒ ๐—จ๐˜€๐—ฒ ๐—–๐—ฎ๐˜€๐—ฒ: ๐——๐—ฟ๐˜† ๐—š๐—ฎ๐˜€ ๐——๐—ฒ๐—ต๐˜‚๐—บ๐—ถ๐—ฑ๐—ถ๐—ณ๐—ถ๐—ฐ๐—ฎ๐˜๐—ถ๐—ผ๐—ป ๐—–๐—ต๐—ฎ๐—บ๐—ฏ๐—ฒ๐—ฟ

Imagine a research lab that has to use dry gas purging to keep an enclosed test globe at a very low moisture level:

๐—–๐—ผ๐—ป๐—ฐ๐—น๐˜‚๐˜€๐—ถ๐—ผ๐—ป

The ETS 90001848 Differential Low Pressure Sensor offers a strong, integrated solution for any application requiring consistent, repeatable environmental testing conditions, especially where pressure differentials are important.

Accurate pressure detection, smooth integration, low-maintenance design, and strong ETS support allow facilities to:

Since 1976, ETS has been “delivering top-tier products, services, and expertise” across sectors, and this is a true fit with that objective.